Cameo Safety and Reliability Analyzer 18.0 SP2 Documentation

Skip to end of metadata
Go to start of metadata

FMEA Items should be described in an FMEA Table. Since FMEA Tables are based on Generic Tables, the toolbar and the Criteria area work in the same manner.

An FMEA Table allows you to analyze the reliability aspect of your model, and provides you with a convenient way to fill-in FMEA Item information using a spreadsheet-like tabular format. Each row in the table represents an FMEA Item. Table columns represent the properties of each FMEA Item in the table. In an FMEA Table, you can:

  • Create a new FMEA Item directly in the table, or add an existing one.
  • Directly edit the properties of FMEA Items in the table.
  • Generate an FMEA analysis report, and export the table into a CSV or HTML file format. 


An FMEA Table has the following columns:

Table column nameDescription
IdAn FMEA Item ID.
NameThe name of an FMEA Item.
ClassificationThe classification of failures (FMEA Items) by certain aspects of a system.
Item

The design model element (Block, Part, Operation or Activity) that is undergoing analysis related to a particular FMEA Item.

Parts or Blocks?

We recommend selecting Parts instead of Blocks, as Blocks can be too generic.

SubsystemAn element identifying the subsystem of a model to which an Item belongs. The valid values are Parts and Blocks.
Failure ModeAn element describing the specific manner in which a component, subsystem, system, process, etc., could potentially fail to meet the design intent.
Local Effect of FailureAn element describing the effect that Failure Mode has on the system element under consideration. Note that an FMEA Item, e.g., a single row of an FMEA Table, can have multiple Local Effects of Failure.
Final Effect of Failure

An element describing the effect that Failure Mode has on an end user or environment.

Every Final Effect of Failure can have a default severity value assigned as its property. To assign a value, open the Specification window of a Final Effect of Failure, and set the desired Severity value.

Usage information

If you add a Final Effect of Failure with specified severity value to a certain row of an FMEA Table for the first time, this value is automatically entered into an appropriate cell of the SEV column. The value is entered even if the cell already has a value specified. You can manually change the severity value that was automatically added to an FMEA Table together with a Final Effect of Failure. This action does not change the default severity value assigned to this specific Final Effect of Failure element.

SEV

A property describing the assessment of the severity of the effect(s) of a potential Failure Mode on a component, subsystem, end-user, or environment. The valid values of this property are 1 to 4 (1 representing the lowest severity).

Click an appropriate column cell to select its value from a drop-down list.

Cause of Failure 

An element indicating the design weakness that is causing a Failure Mode. Note that an FMEA Item, I.e. a single row of an FMEA Table, can have multiple Causes of Failure.

Every Cause of Failure can have a default occurrence and/or detectability value(s) assigned as its property(ies). To assign an occurrence or value, open the Specification window of a Cause of Failure, and set the desired Occurrence and/or Detectability value(s).

Usage information

If you add a Cause of Failure with a specified occurrence or detectability value (or both of them) to a certain row of an FMEA Table for the first time, this value is automatically entered into an appropriate cell of the OCC or DET column. The value is entered even if the cell already has a value specified. You can manually change the occurrence or detectability value that was automatically added to an FMEA Table together with a Cause of Failure. This action does not change the default occurrence or detectability value assigned to this specific Cause of Failure element.

OCC

Occurrence is a property showing the likelihood that a specific Cause of Failure will occur. The valid values of this property are 1 to 5 (1 representing the lowest probability of occurrence).

Click an appropriate column cell to select its value from a drop-down list.

Prevention Control

and

Detection Control

Prevention Control is an element describing the measures for preventing the occurrence of a possible Failure Mode. Detection Control is an element describing the measures for detecting a Failure Mode, if it occurs.

Usually, in an FMEA Table, each Prevention Control and Detection Control value is related to a specific Cause of Failure. Therefore, after adding a Cause of Failure to a specific row of a table, you can quickly reuse the Prevention Control and/or Detection Control value(s) that are associated with it in another row of the same table. To reuse the values:

  1. Right-click the row in which you want to reuse a previously associated Prevention Control and/or Detection Control value(s). Note that this row should already have a Cause of Failure element specified.
  2. From the open menu, select Reuse Design Controls. If the Cause of Failure has a reusable Detection Control and/or Prevention Control element(s), the Reuse Design Controls dialog opens.
  3. In the open dialog, select the element(s) you want to reuse as Prevention Control and/or Detection Control value(s), and click OK.

The appropriate cell(s) in the Prevention Control and/or Detection Control column(s) of an FMEA Table are filled with the selected value(s).

DET

Detectability measures the likelihood of discovering a possible failure prior to its occurrence. The valid values of this property are 1 to 5 (1 representing the highest detectability).

Click an appropriate column cell to select its value from a drop-down list.

OxDThe product of OCC and DET ratings.
RPNA risk priority number is a derived property calculated by using a customizable function. By default, the function includes SEV, OCC, and DET values.
Hazard Analysis Reference

Hazard Analysis Reference to a Safety Analysis Item shows that the safety aspect has been analyzed for this particular FMEA Item.

Required Hazard Analysis

A property indicating whether or not an FMEA Item requires hazard analysis. The valid values of this property are true or false. If you create your project using the Safety and Reliability Analysis Project template, the FMEA Items marked as requiring hazard analysis are added to the FMEAs to Be Analyzed package. If not, you need to configure a Smart Package to manually filter these elements. When a specific FMEA Item is addressed in a Safety Analysis Item, it is removed from the FMEAs to Be Analyzed package after refreshing your model.

Recommended ActionThe description of a recommended action to take that will reduce RPN. All critical or significant failures (FMEA Items) should have recommended actions associated with them. Recommended actions should be focused on design, and directed towards mitigating the Cause of Failure or eliminating the Failure Mode.
MitigationThe reference to any element that mitigates a failure.
ResponsibilityA property indicating the person responsible for completing a Recommended Action.
Target Completion DateA property defining the completion date of a Recommended Action. The value of the Target Completion Date property can be specified in the Date and Time Settings dialog.
Action TakenA property describing what actions have been taken, and the results of these actions.

Reduced SEV

A property assessing the seriousness of the effect(s) that a potential Failure Mode has on a component, subsystem, end-user, or environment after the mitigation. The valid values of this property are 1 to 4 (1 representing the lowest severity).

Click an appropriate column cell to select its value from a drop-down list.

Reduced OCC

Reduced occurrence is a property that shows the likelihood that a specific Cause of Failure will occur after the mitigation. The valid values of this property are 1 to 5 (1 representing the lowest probability of occurrence).

Click an appropriate column cell to select its value from a drop-down list.

Reduced DET

Reduced detectability measures the likelihood of discovering a possible failure after the mitigation. The valid values of this property are 1 to 5 (1 representing the highest detectability).

Click an appropriate column cell to select its value from a drop-down list.

Reduced OxDThe product of the Reduced OCC and Reduced DET ratings.
Reduced RPNA reduced risk priority number is a derived property calculated by using a customizable function. By default, the function includes Reduced SEV, Reduced OCC, and Reduced DET values.


Creating an FMEA Table

To keep your model clean and simple, you should create an FMEA Table in the package that contains FMEA Items that are to be included in the table.
 

To create an FMEA Table


  1. Do one of the following:
    • Right-click the Package in which you want to create an FMEA Table, and, from the menu, select Create Diagram.
    • Select the Package in which you want to create an FMEA Table, and click the Create Diagram button on the main toolbar.
  2. Click FMEA Table under the Safety and Reliability Analysis group.
  3. If needed, change the name of the newly created FMEA Table.

A new FMEA Table has been created in the selected Package. Now you should add FMEA Items to the table, as described in the next section.
 

Adding FMEA Items to an FMEA Table

There are two ways to add FMEA Items to an FMEA Table:

  • Create new FMEA Items directly in the table.
  • Add existing FMEA Items to the table.
     

Productivity tip

To make your work quicker, you can add existing FMEA Items to an FMEA Table by dragging them directly to the table. Simply select one or more FMEA Items in the model browser, and drag them to an FMEA Table. New rows for the added elements are created automatically.

 

To create a new FMEA Item in an FMEA Table


  • Do one of the following:

-Click the Add New button on the table toolbar.
-Press Insert (Cmd+I on Mac OS).

A new row is added to the end of the table. This row already contains a newly created Safety Analysis Item, which also shows up in the containment tree of your model (inside the package containing the FMEA Table on which you are working). Now, you can define the created FMEA Item and its properties directly in the table by double-clicking an appropriate cell.
 

Model structure information

To have a clear model structure, you should create FMEA Items in dedicated Packages.

 

To add an existing FMEA Item to an FMEA Table


  1. Do one of the following:
    • Click the Add Existing button on the table toolbar.
    • Press Ctrl+Insert (Cmd+E on Mac OS).
  2. In the open dialog, select the FMEA Item you want to add to the table. To select multiple elements, click , and add the desired FMEA Items to the Selected elements area on the right side of the dialog.
  3. Click OK.

Selected FMEA Item(s) are now added to the FMEA Table as new row(s). You can change the properties of the added elements directly in the table by double-clicking an appropriate cell.
 

Readability tip

To promote information readability, you can wrap table text the following way:

  1. Click on the table toolbar.
  2. In the drop-down menu, select Wrap Text.
  • No labels