SysML Plugin 18.3 Documentation

Skip to end of metadata
Go to start of metadata

An Interface Control Document (ICD) tables describes the interfaces between systems or/and subsystems. That helps to ensure a compatibility between system components.

The purpose of Whitebox ICD Table is to show how Parts are connected via Ports/interfaces. This table collects all Parts of the context element. Those Parts are connected through the Ports/interfaces using Connector relationship. You can visually identify what kind of Ports/interfaces (Port A and Port B) and flows (Item Flow) are used to connects two Parts (Part A and Part B).

Example

 In the row 1, the Part Controller sends the control signal to the Part Boiler through the Ports b and c. The Controller receives the Status signal from the Boiler through the Ports c and b. In the row 2,  the Part Controller sends the flow Elec Power to the Part Boiler through the Ports bp and p in.
Whitebox ICD Table


A Whitebox ICD Table consists of the following columns.

Column nameDescription
#A row number.
Part ADisplays a Part that is connected with Part B.
Port ADisplays a Port  that is connected with Port B.
Port A FeaturesDisplays all the properties of the Port A.
Item FlowDisplays the flow kind and its direction which flows through the Connector between two Parts (Part A and Part B).
Port BDisplays a Port  that is connected with Port A.
Port B FeaturesDisplays all the properties of the Port B.
Part BDisplays a Part  that is connected with Part A.