Cameo DataHub additionally supports text style in rich-text files (RTF) and image and other objects, e.g., Embedded Excel spreadsheet and Words files, in object linking and embedding (OLE).
To enable the RTF and OLE support
When you right-click the DOORS Data Source next time after you have enabled RTF for text support, there will be two more commands available to disable RTF for text support or enable RTF for OLEs support.
RTF and OLE command | Function | |
---|---|---|
Enable RTF for text support | Allows the support of text styles in RTF when copying data from DOORS to MagicDraw. | |
Disable RTF for text support (available after selecting Enable RTF for text support) | Suspends the RTF and OLE support. | |
Enable RTF for OLEs support (available after selecting Enable RTF for text support) | Copies text styles and image as an OLE object from DOORS to MagicDraw.
|
If you have selected only Enable RTF for text support but does not select Enable RTF for OLEs support after right-clicking the DOORS Data Source for the second time, copying elements, e.g., Requirements from DOORS to MagicDraw will include only text styles, e.g., bold, italic, underline, strikethrough, superscript, and subscript. However, any image in the data will not be copied.
If you have selected Enable RTF for text support and select Enable RTF for OLEs support after right-clicking the DOORS Data Source for the second time, copying elements, e.g., Requirements from DOORS to MagicDraw will include both text styles and image as an OLE object.