This page describes how to simulate the Humidifier example model in Dymola. Learn more about Humidifier sample model >>
| Info |
|---|
You can find the Humidifier sample model in: - the modeling tool: Welcome window > Samples > Simulink and Modelica Transformation > Humidifier.
- the Installation directory: <modeling tool installation directory>\samples\SysML\Simulink and Modelica Transformation\Humidifier.
|
...
- Export the HumidifierSystem Block to the Modelica file. To learn more, refer to the Modelica export page.
- Download and install Dymole in your system. To learn more, refer to the Dymola page.
- Launch the Dymola.
- Click File > Open > Load... and select the saved HumidifierSystem.mo file from your directory. The Humidifier System model is displayed in the Package Browser.

- In the Graphics tab toolbar, click Check to check for syntax and semantic errors in the model. The Logs panel displays whether the model is ready for simulation.

- Setup the simulation run for the model:
a. Select the Simulation tab and in its toolbar click
.
b. In the Simulation Setup dialog, specify the Start time value to 0 and the Stop time value to 3600 seconds.
c. Click OK.

In the Simulation tab toolbar, click Simulate.

| Info |
|---|
When the simulation is completed, the output is displayed in the panel at the bottom and the HumidifierSystem variables are displayed in the Variable Browser. |
- To see the input and output of the EnvironmentModel, variables from the Variable Browser must be chosen. Selecting EnvironmentModel > _Environment > room > humidity_out will display the humidity level of the room overtime on the plotting window.
...