Abbreviation

COR2127

Message

Broken synchronization between '<conjugated interface name>' Resource Interface and '<original interface name>' original interfaces.

Description

Incorrect synchronization between Conjugated Resource Interface and Original Interface

Severity

Warning

Context element

Resource Interface

Solvers

  • Synchronize Conjugated Resource Interface with Original Interface:
    • set the opposite Flow Property directions of the Conjugated Resource Interface.
    • delete any unmatched and/or duplicated Flow Properties in the Conjugated Resource Interface.
    • create a matching Flow Property for the Conjugated Resource Interface but in the opposite direction of the Original Interface. 

Example

Using the solver, the missing flow property was added